Skip to main content

Hiscon Industries

● GERMAN TECHNOLOGY AUTOCLAVED AERATED CONCRETE

Hiscon AAC Blocks

Explore the block, see how it fits into a wall, and find the specifications for your project.

*Illustrative 3D representation based on standard modular 600×200×200mm dimensions.

Single Block • 3/4 Perspective
Interactive Product Explorer

Precision Down to the Micropore

Drag to rotate 360° or select a hotspot to inspect the cellular matrix, wire-cut tolerances, and modular dimensions.

Drag to rotate • Touch friendly
1

Surface Texture & Micro-Pores

Millions of microscopic, non-connected air cells created via precision aeration reaction. This cellular matrix drastically halts thermal convection, absorbs sound waves (STC ~42dB), and blocks water absorption compared to traditional bricks.

Thermal: 0.16–0.24 W/m·K Acoustic: ~42 dB Dry Density: 550–750 kg/m³
2

High-Precision Cut Edges

Automated high-speed wire cutting guarantees sharp, consistent edges within ±1.0mm height and ±1.5mm length/thickness tolerances. Allows builders to use thin-bed jointing mortar (3–5mm), eliminating thermal bridging and saving up to 75% on mortar costs.

Joint Mortar: 3–5 mm Cutting Accuracy: ±1.0 to 1.5 mm Zero Plaster Chipping
3

Standard Modular Proportions

Standard modular format (600mm length × 200mm height) provides the volume equivalent of approximately 8 to 9 red clay bricks. Masonry laying speed increases up to 300% with significantly less labor fatigue and structural dead-load reduction.

Length: 600 mm Height: 200 mm Thickness: 100 / 150 / 200 / 230 mm
Laboratory Verified

Technical Specifications

Engineered in strict accordance with Bureau of Indian Standards (IS 2185 Part 3).

Technical Review Note for Hiscon Engineering

The standard product specification tables list minimum compressive strength classes of 4.0 N/mm² (Grade 1) and 5.0 N/mm² (Grade 2), while the marketing comparison table indicates 3.0–4.0 N/mm². Both figures are presented transparently here for engineering appraisal pending project-specific test certificates from Hiscon’s in-house laboratory.

A) Dimensional Accuracy (Cutting Tolerance)

Dimension Parameter Tolerance Standard
Length of the block ± ≤ 1.5 mm (repetitive)
Height of the block ± ≤ 1.0 mm (repetitive)
Thickness of the block ± ≤ 1.5 mm (repetitive)

B) Compressive Strength & Density Classes

Compressive Strength Class* Dry Density Range
Grade 1: Min, 4 N/mm² 550 kg/m³ to 650 kg/m³
Grade 2: Min, 5 N/mm² 650 kg/m³ to 750 kg/m³
*Tested as per IS 2185 Part 3 autoclaved aerated concrete masonry standards.

C) Drying Shrinkage & Lab Testing

Maximum Average Shrinkage 0.03 mm/m
Laboratory Casting Capabilities Raw material inspection & custom batch test casting available upon request.

D) Fire Rating & Thermal Performance

Fire Resistance (200 mm wall) Up to 4 Hours (as per PCA)
Thermal Conductivity (k) 0.16 – 0.24 W/m·K
Sound Transmission Class (STC) Approx. 40 to 44 dB
Material Benchmarking

AAC Blocks vs. Traditional Red Clay Bricks

Engineered wall assemblies deliver drastic weight savings, faster installation, and superior energy efficiency.

Hiscon AAC Block Masonry

Modern Engineering
600 × 200 mm
600 × 200 mm
300mm
600 × 200 mm
300mm
600 × 200 mm
600 × 200 mm

Joint Thickness: 3–5 mm thin-bed jointing mortar. Flat face alignment eliminates thick plaster coats.

Volume Equivalence: 1 AAC Block ≈ 8 to 9 Red Bricks. 3× faster wall construction.

Conventional Red Clay Brick

Outdated Method

Joint Thickness: 10–15 mm cement-sand mortar. High thermal bridging, heavy weight, and excessive curing water needed.

Wastage: 10% to 15% site breakage during transport and handling.

# Basis of Difference Hiscon AAC Blocks Traditional Red Bricks
1 Size Range Wide standard size range and customizable options Available in only one or two standard sizes; not customizable
2 Construction Speed Bigger sizes, dimensional accuracy and fewer joints ensure higher construction speed Smaller sizes, less dimensional accuracy and more joints reduce construction speed
3 Mortar Joint Thickness Thin mortar joints in the range of 3–5 mm Thick mortar joints of minimum 10–15 mm
4 Green Product Made from non-toxic materials, utilizes fly ash; zero topsoil destruction Made from natural topsoil clay, causing ecological degradation
5 Seismic Resistance Reduces structure dead load, significantly increasing earthquake safety Increases dead load, elevating structural seismic vulnerability
6 Fire Resistance 200 mm thick wall provides up to 4 hours fire rating (as per PCA) 200 mm thick red brick wall provides up to 2 hours fire rating
7 Moisture Resistance Less water absorption due to unconnected microscopic pores High water absorption through capillary action causing efflorescence
8 Thermal Conductivity Low thermal conductivity, drastically reducing interior heat transfer High thermal conductivity causing heavy indoor heat transfer and high AC bills
9 Sound Absorption Excellent sound insulation properties (~40 to 44 dB STC) Poor sound attenuation properties
10 Dry Density Varies between 550 – 750 kg/m³ (approx 1/3 of clay bricks) Dense: 1600 – 1920 kg/m³
11 Compressive Strength Consistent high strength (Grade 1: 4 N/mm²; Grade 2: 5 N/mm²) Highly inconsistent, averaging approx. 2.5 N/mm²
12 Weight Lightweight: cuts structural foundation concrete and steel reinforcement Heavy: demands thicker RCC columns and beams
13 Termite & Pest Resistance Inorganic composition prevents termite breeding and pest harborage No inherent pest-resistant qualities
14 Curing Period Minimal to zero water curing needed when using thin-bed mortar Requires extensive water curing for 14–21 days, raising electricity and labor costs
15 Wastage & Breakage Minimal breakage; nearly 100% on-site utilization Average 10% to 15% wastage and brick rubble loss
16 Overall Cost Savings Higher cumulative savings across structural steel, mortar, plaster, and labor Higher overall construction lifecycle cost
Engineered Resilience

Custom Solutions Tailored for Every Climate

Whether building in scorching tropical heat or sub-zero mountain regions, Hiscon AAC Blocks adapt to protect your structure.

☀️

1. For Hot and Humid Climates

High Thermal Insulation

Engineered with enhanced thermal barrier properties to arrest solar heat radiation through external facades. Maintains comfortable indoor temperatures, cutting cooling electricity consumption by up to 30%.

Moisture & Mold Resistance

The non-connected cellular pore matrix resists moisture penetration, preventing damp patches, efflorescence, and dangerous mold growth during torrential monsoon seasons.

❄️

2. For Cold Climates

Improved Thermal Retention

High thermal mass traps indoor heating energy and prevents heat leakage through exterior walls, reducing winter fuel and heating expenses.

Frost & Freeze-Thaw Resistance

Autoclaved crystalline matrix withstands sub-zero freezing temperatures without cracking or surface spalling, ensuring permanent structural integrity in cold terrains.

Quality & Accreditation

Official Resources & Certificates

Download technical catalogues and view official BIS and ISO compliance documents.

Hiscon Corporate Product Brochure

Comprehensive technical specifications, installation guidelines, size tables, and physical properties.

Download Brochure (PDF)

Bureau of Indian Standards (BIS)

Licence No. 8200085613 certifying conformity with IS 2185 (Part 3): 1984 autoclaved aerated concrete masonry blocks.

View BIS Licence Certificate

ISO 9001:2015 Quality Management

Internationally audited standard for automated manufacturing, raw material quality control, and testing protocols.

View ISO 9001 Certificate
Direct Factory Pricing

Request a Project Quote

Whether planning an upcoming project or requiring urgent site delivery, our technical sales engineers will calculate your exact requirements.

Or instant support: Chat on WhatsApp